|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
BATTERY CHARGER SYSTEMS PBLDU Series 7 0 - 2 8 0 W AT T S D C U P S L I N E A R Features * * * * * * * * * * Uninterrupted DC UPS Separate load and battery outputs Superior line & load regulation Highly efficient linear design Rack or chassis mount C-tick approved Battery charging management system DC OK and Battery OK alarm Low voltage disconnect Internal battery back up option SPECIFICATIONS INPUT Input Voltage Frequency Input Protection Input Fuse 240VAC 5% full output current. Other voltages on request 50Hz-60Hz Yes Yes Visual LED Indicators DC OK Indicator Battery OK Indicator Battery On Line Indicator Battery Status Indicator Temperature Shutdown DC OK Battery OK Battery On Line Yes Yes Yes Charge: Green, Discharge: Red Optional Yes Yes Yes OUTPUT Output Voltage Output Currents Output Ripple Line Regulation Load Regulation Temperature Coefficient Transient Response Overvoltage Protection Overcurrent Protection See table See table 0.5mV pk-pk max. (100Hz-120Hz) 0.1% max. 0.5% max. 50ppm per C typical (250ppm per C max.) <3%, 0.5mS (50% load change, recover to 2% of V out) SCR crowbar, factory set at 120% Vout 5% Foldback current limiting 115% +7% max. VOLT FREE ALARM CONTACTS STANDARDS and APPROVALS Safety C-Tick/EMC Standards AS3260. Austel approved AS/NZS CSIPR11 Group 1 Class B MECHANICAL Dimensions RM Rack Mount: 19"x2Ux416mm RM-S Rack Mount Short 19"x2Ux234mm WM Wall Mount: 371x322x123mm CM Chassis Mount: 322x187x90mm Rack Mount: IEC input Wall & Chassis Mount: 7-way 9.5mm barrier terminal block Rack Mount: Barrier terminal block Wall & Chassis Mount: 2.54mm PCB header ENVIRONMENTAL Operating Temperature Derating Cooling 0C to 50C at full load 50C to 70C derate linearly to 40% Natural convection Alarm Contacts Connections OPERATING Isolation Efficiency Batteries Primary to secondary: 3.5kV 1 min 60%-80% depending on output voltage 12V, 6.5Ah sealed lead acid batteries are optional within the 19" rack mount. For expanded battery capacity, external battery enclosures may be provided. Thermal shutdown. Auto electronic reset High Temperature 286 BATTERY CHARGER SYSTEMS PBLDU Series 7 0 - 2 8 0 W AT T S D C U P S L I N E A R Selection Table During mains operation the PBLDU series can supply load current from the selection table and provide controlled charge current to the battery. The unit has additional capacity to supply 175% surge current if required by the load. When operating on battery back up only the stated load current can be supplied. MODEL NUMBER PBLDU-12C05CM PBLDU-12C05CM PBLDU-12C10RM PBLDU-12C10RM PBLDU-24C05CM PBLDU-24C05RM PBLDU-24C10CM PBLDU-24C10RM PBLDU-48C05CM PBLDU-48C05RM VDC 13.8V 13.8V 13.8V 13.8V 27.6V 27.6V 27.6V 27.6V 55.2V 55.2V OUTPUT ILOAD 3.75A 3.75A 7.5A 7.5A 3.75A 3.75A 7.5A 7.5A 3.75A 3.75A IBATT 1.25A 1.25A 2.5A 2.5A 1.25A 1.25A 2.5A 2.5A 1.25A 1.25A OUTPUT POWER 70W 70W 140W 140W 140W 140W 280W 280W 280W 280W Note: To order models with batteries included. Please add "-BAT" at end of model number. (Rack Mounted Version Only) Technical Illustrations CHASSIS MOUNT Your dependable power partner - www.powerbox.com.au 287 BATTERY CHARGER SYSTEMS 288 PBLDU Series 7 0 - 2 8 0 W AT T S D C U P S L I N E A R Technical Illustrations RACK MOUNT - Including batteries PBLDU Series 7 0 - 2 8 0 W AT T S D C U P S L I N E A R BATTERY CHARGER SYSTEMS Technical Illustrations RACK MOUNT SHORT-S Your dependable power partner - www.powerbox.com.au 289 |
Price & Availability of PBLDU-12C05CM |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |